The NAVIGUIDE 4000 Manual Ship Steering System is based on network solutions which easily can be modified or expand to requirements.

See below for an overview of the NAVIGUIDE 4000 performances:

ENVIRONMENT  
Ambient temperature range (operation) -15° C to +55° C
Ambient temperature range (storage) -25° C to +70° C
Protection grade (installed) IP32 to DIN 40050
Magnetic clearance 0.40m
Environmental testing in accordance with EN 60945 (IEC 945 +A1)  
Cable connection Clamp-type terminals
Protection grade IP32 to DIN 40050
Dimensions 151 mm Height, 392 mm Width, 425 mm Depth
Weight 3 kg
Power requirements 24 VDC (18 V to 36 V)
Maximum ripple conten 4 V pp
Power consumption 10 W max
Reverse polarity protection Built-in

 

INPUTS  
Rudder order signal (follow-up hand wheel) ±10 V ±120° max rudder angle potentionmeter resistance 2kW with center tap
Rudder angle feedback signal ±10 V ±120° max rudder angle potentionmeter resistance 2kW with or without center tap
Speed input 200 p/nm or NMEA 0183
External system ±10 V ±120° max rudder angle
Steering mode status  
Override status  
Mute  
Central alarm NMEA 0183

 

OUTPUTS

DC Solenoid Valves  
Outputs Two for port, two for starboard (solid-state relays)
Voltage 12 VDC to 110 VDC
Rating 2.0 A max
Inputs "Pump on” sense contact closure inputs

 

AC Solenoid valves  
Outputs Two for port, two for starboard (solid-state relays)
Voltage 24 VAC to 230 VAC
Rating 1.0 A max.
Inputs "Pump on” sense contact closure inputs

 

PROPORTIONAL RUDDER ORDER/ ERROR  
Outputs 80 mV/° to 350 mV/° (isolated) or 4 mA to 20 mA (isolated)

 

OUTPUTS AND INTERFACES  
Central alarm NMEA 0183
Voyage Data Recorder (VDR)  
CAN to IEC 61162-3 for bus interface units and additional steering control

 

STATUS AND ALARM  
System alarm Potential-free contacts
External system status 115v AC, 0,5A /30v DL
Override alarm  

 

POWER FAILURE ALARM  
Primary supply Potential-free contacts
Backup supply